Uncoated
Insulating Glass
| Minimum
Size |
Maximum
Size |
| Annealed |
|
8" x 18"
(203 mm x 457 mm) |
84" x 144"
(2134 mm x 3658 mm) |
| Heat
processed |
|
12" x 12"
(305 mm x 305 mm) |
84" x 144"
(2134 x 3658 mm) |
Premium over-sized maximum: 84" x 165" (2134 mm x 4191 mm) or 96" x 144" (2438 mm x 3658 mm). Premium over-sized maximum for silk-screened glass and for heat-soaked glass is 84" x 165" (2134 mm x 4191 mm). A technical reiew is required for all over-sized requests.
1. Viracon's insulating glass units have been CBA rated with the Insulating Glass Certification Council (IGCC) in accordance with ASTM Specifications E-773 and E-774. ASTM E 2190 now supersedes ASTM E-773 and E-774. In 2005 IGCC has begun certifying insulating glass to ASTM E 2190. Viracon's insulating glass will now be IGCC certified to ASTM E 2190.
2. In some cases, insulating glass units may require
heat processing. Refer to heat processing comments
on page 14 for further product information.
Solarscreen High-Performance Reflective and Low-E
Coated Insulating Glass
| Minimum
Size |
Maximum
Size |
| Annealed |
|
8" x 18"
(203 mm x 457 mm) |
84" x 144"
(2134 mm x 3658 mm) |
| Heat
processed |
|
12" x 12"
(305 mm x 305 mm) |
84" x 144"
(2134 mm x 3658 mm) |
Premium over-sized maximum: 84" x 165" (2134 mm x 4191 mm) or 96" x 144" (2438 mm x 3658 mm). Premium over-sized maximum for silk-screened glass and for heat-soaked glass is 84" x 165" (2134 mm x 4191 mm). A technical reiew is required for all over-sized requests.
1. In some cases, insulating glass units may require
heat processing. Refer to heat processing comments
on page 14 for further product information.
2. Coated Glass Inspection Guidelines. Viracon's
coated glass products comply with ASTM Standard
C 1376.
Pinholes-Inspect glass from a distance of 10 ft.
(3 m) in transmission, at a viewing angle of 90°
to the specimen, against a bright uniform background.
If a pinhole is readily apparent, the following
criteria apply: Pinholes larger than 1/16"
(1.6 mm) in diameter are not allowed in 80 percent
of the central glass area. Pinholes larger than
3/32" (2.4 mm) are not allowed in the outer
20 percent of the glass area. No more than two
readily apparent blemishes are allowed in a 3"
(75 mm) diameter
circle and no more than five readily apparent
blemishes are allowed in a 12" (300 mm) diameter
circle.
• Uniformity-When viewing coated glass from
a minimum distance of 10 ft. (3 m), color variation
may occur from one unit to another. This can be
caused by variations within the float glass substrate
and normal production variations, and this is
not considered a defect. All Viracon commercial
glass products conform to industry color standards.
• Distortion-Various factors involved in
heat processing, insulating air spacers and frame
binding may distort reflected objects viewed on
the glass surface. These are not considered defects
of the coated glass or the final fabricated product.
• Scratches-Inspect glass from a distance
of 10 ft. (3 m). Scratches up to 2" (50 mm)
are allowed in 80 percent central glass area,
and scratches up to 3" (75 mm) are allowed
in the outer area. Concentrated scratches or abraded
areas are not allowed.
Solarscreen Insulating Spandrel Glass
| Minimum
Size |
Maximum
Size |
12" x 36"
(305 mm x 914 mm) |
84" x 144"
(2134 mm x 3658 mm) |
Premium over-sized maximum: 84" x 165" (2134 mm x 4191 mm). A technical review is required for all over-sized requests.
1. Viracon designs its spandrel glass for glazing
against a uniform, opaque background. We do not
recommend its use in transoms, partitions or other
areas where a uniform, opaque background is unavailable.
2. Reflective Spandrel Glass Inspection Guidelines
• View spandrel glass from a distance of
15 ft. (4.6 m) under natural daylight conditions.
Color and reflectance may vary when viewed under
a uniform, opaque background. This is not considered
a defect.
• When viewing spandrel glass under similar
conditions, reflected pinholes and scratches are
not considered defects if they are unobtrusive.
Viraspan for Uncoated Insulating
Glass
| Minimum
Size |
Maximum
Size |
12" x 12"
(305 mm x 305 mm) |
84" x 144"
(2134 mm x 3658 mm) |
Premium over-sized maximum: 84" x 165" (2134 mm x 4191 mm). A technical review is required for all over-sized requests.
1. Viracon designs its spandrel glass for glazing
against a uniform, opaque background. We do not
recommend its use in transoms, partitions or other
areas where a uniform, opaque background is unavailable.
2. Viraspan Spandrel Glass Inspection Guidelines
• View spandrel glass from a distance of
15 ft. (4.6 m) under natural daylight conditions.
Color and reflectance may vary when viewed under
a uniform, opaque background. This is not considered
a defect.
• When viewing spandrel glass under similar
conditions, reflected pinholes and scratches are
not considered defects if they are unobtrusive.
3. You can use Viraspan in structurally glazed
applications. However, a clear edge may be visible.
Contact Viracon's Architectural Inside Sales Department
for more information.
4. Viracon reserves the right to change substrate
glass suppliers. As a result, this may affect
perceived colors of our Viraspan samples. Approval
of all glass colors is based on 12" x 12"
(305 mm x 305 mm) samples, which are ordered for
each project.
Heat-Processed Glass (Heat Strengthened
and Tempered)
1. Glass cutting and fabrication is completed
prior to heat processing.
2. Viracon's two types of heat-processed glass
comply with ASTM Standard C1048. Surface compression
of heat-strengthened glass with thicknesses of
1/4" (6 mm) and less is 4,000-7,000 psi.
Surface compression for 5/16" (8 mm) and
3/8" (10 mm) heat-strengthened glass is 5,000-8,000
psi.* For fully-tempered glass, the minimum surface
compression is 10,000 psi. It also complies with
ANSI Z97.1 and CPSC 16 CFR 1201 safety glazing
standards.
*Because of reader repeatability and instrument
tolerances, Viracon's tolerance for heat-strengthened
glass surface compression is +/- 1,000 psi.
RECOMMENDED CLEARANCES

Note:
The maximum sizes listed are shown to illustrate
production limits. These sizes are unavailable
as finished products. Maximum piece size for annealed
glass under any condition is 50 sq. ft. (4.65
sq.m.) Maximum size for heat-treated glass under
any condition is 65 sq. ft. (6.04 sq.m.) Maximum
unit weight is 750 pounds (340 kg). The premium over-weight maximum is 2000 pounds (907 Kg). A technical review is required for all over-weight requests.
For more information on insulating glass or additional
literature, call 800-533-2080 or
e-mail
us