1" (25mm) Insulating VE1-2M
1/4" (6mm) clear with VE-2M #2 and 60% coverage DigitalDistinctions™ White #2
1/2" (13.2mm) space - air filled
1/4" (6mm) clear
Reflected Color
Transmitted Color
Performance Data
Show data as:
Transmittance
Visible Light
37%
Solar Energy
17%
UV
4%
Reflectance
Visible Light-Exterior
27%
Visible Light-Interior
30%
Solar Energy
31%
NFRC U-Value
Winter
0.30 (hr x sqft x °F)
Summer
0.26 (hr x sqft x °F)
Shading Coefficient
0.26
Relative Heat Gain
56Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.23
LSG
1.61
Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.
Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.