VS26-08 1" (25mm) Insulating with RoomSide Low-E - Viracon
Search
/* Start the Loop */
Products

1" (25mm) Insulating with RoomSide Low-E VS26-08

1" (25mm) Insulating with RoomSide Low-E VS26-08

1/4" (6mm) Solarblue™ with VS-08 #2
1/2" (13.2mm) space - air filled
1/4" (6mm) RoomSide™ Low-E #4

Reflected Color
Transmitted Color
Diagram

Performance Data

Show data as:

Transmittance

Visible Light
5%
Solar Energy
3%
UV
1%

Reflectance

Visible Light-Exterior
20%
Visible Light-Interior
32%
Solar Energy
16%

NFRC U-Value

Winter
0.29 (hr x sqft x °F)
Summer
0.27 (hr x sqft x °F)
Shading Coefficient
0.13
Relative Heat Gain
30Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.11
LSG
0.45

Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.

Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.