1" (25mm) Insulating with RoomSide Low-E VUE24-50
1/4" (6mm) Optiwhite™ with VUE-50 #2
1/2" (13.2mm) space - argon filled
1/4" (6mm) RoomSide™ Low-E #4
Reflected Color
Transmitted Color
Performance Data
Show data as:
Transmittance
Visible Light
50%
Solar Energy
21%
UV
6%
Reflectance
Visible Light-Exterior
12%
Visible Light-Interior
11%
Solar Energy
36%
NFRC U-Value
Winter
0.20 (hr x sqft x °F)
Summer
0.17 (hr x sqft x °F)
Shading Coefficient
0.28
Relative Heat Gain
59Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.25
LSG
2
Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.
Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.