1-3/4" (44mm) Triple Insulating (Single Coating) VE33-42
1/4" (6mm) Majestic Grey with VE-42 #2
1/2" (13.2mm) space - air filled
1/4" (6mm) clear
1/2" (13.2mm) space - air filled
1/4" (6mm) clear
Reflected Color
Transmitted Color
Performance Data
Show data as:
Transmittance
Visible Light
25%
Solar Energy
14%
UV
8%
Reflectance
Visible Light-Exterior
13%
Visible Light-Interior
19%
Solar Energy
13%
NFRC U-Value
Winter
0.22 (hr x sqft x °F)
Summer
0.23 (hr x sqft x °F)
Shading Coefficient
0.26
Relative Heat Gain
55Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.22
LSG
1.14
Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.