1" (25mm) Insulating with RoomSide Low-E VRE26-54
1/4" (6mm) Solarblue™ with VRE-54 #2
1/2" (13.2mm) space - air filled
1/4" (6mm) RoomSide™ Low-E #4
Reflected Color
Transmitted Color
Performance Data
Show data as:
Transmittance
Visible Light
31%
Solar Energy
16%
UV
9%
Reflectance
Visible Light-Exterior
16%
Visible Light-Interior
14%
Solar Energy
16%
NFRC U-Value
Winter
0.24 (hr x sqft x °F)
Summer
0.21 (hr x sqft x °F)
Shading Coefficient
0.25
Relative Heat Gain
54Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.22
LSG
1.41
Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.
Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.