Search
/* Start the Loop */
Products

1-3/4" (44mm) Triple Insulating (Double Coating) VS1-20

1-3/4" (44mm) Triple Insulating (Double Coating) VS1-20

1/4" (6mm) clear with VS-20 #2
1/2" (13.2mm) space - air filled
1/4" (6mm) clear with VE-85 #4
1/2" (13.2mm) space - air filled
1/4" (6mm) clear

Reflected Color
Transmitted Color

Performance Data

Show data as:

Transmittance

Visible Light
16%
Solar Energy
8%
UV
4%

Reflectance

Visible Light-Exterior
24%
Visible Light-Interior
32%
Solar Energy
21%

NRFC U-Value

Winter
0.20 (hr x sqft x °F)
Summer
0.21 (hr x sqft x °F)
Shading Coefficient
0.17
Relative Heat Gain
38Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.15
LSG
1.07

Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.

Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.