Search
/* Start the Loop */
Products

1/4" (6mm) Monolithic VP30-22

1/4" (6mm) Monolithic VP30-22

1/4" (6mm) Optigray™ with VP-22 #2 and 30% coverage V175 High-Opacity White #2

Reflected Color
Transmitted Color

Performance Data

Show data as:

Transmittance

Visible Light
13%
Solar Energy
11%
UV
8%

Reflectance

Visible Light-Exterior
14%
Visible Light-Interior
36%
Solar Energy
11%

NRFC U-Value

Winter
0.92 (hr x sqft x °F)
Summer
0.81 (hr x sqft x °F)
Shading Coefficient
0.38
Relative Heat Gain
88Btu/(hr x sqft)
Solar Heat Gain Coefficient (SHGC)
0.33
LSG
0.39

Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software.

Winter and Summer U-Values are the only performance values available for spandrel glazing. The U-Values for spandrel glazing are the same as the corresponding vision unit. The spandrel color does not impact U-Value.